Show simple item record

dc.rights.licenseAtribución-NoComercial 4.0 Internacional
dc.contributor.authorBurbano Jaramillo, Juan Carlos
dc.contributor.authorPellegrini, Luiz Felipe
dc.contributor.authorde Oliveira Jr., Silvio
dc.date.accessioned2019-06-28T02:11:29Z
dc.date.available2019-06-28T02:11:29Z
dc.date.issued2011
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/37994
dc.description.abstractThe study of absorption refrigeration systems has had increasing importance in recent years due to the fact that the primary energy that is used in an absorption system can be heat available from a residual source or even a renewable one. Therefore, these systems not only use energy that would be rejected by the environment, but also they avoid the consumption of expensive fossil or electrical energies. The production cost of the mechanical work necessary to obtain a kW of refrigeration for mechanical compression cycle is normally higher than the cost for recovering the needed heat to obtain the same kW in an absorption cycle. Also, the use of these systems reduces impact on the environment by decreasing the emission of CO2. We intend to show the performance of a hybrid absorption-ejecto compression chiller compared to conventional double- and single-effect water/lithium bromide systems, by means of an exergetic and exergoeconomic analysis of these configurations in order to calculate the exergy-based cost of a final product. The vapor compression refrigeration system is included in the results, as a comparisson to the performance of the absorption refrigeration systems analyzed.
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia Sede Medellín
dc.relationhttp://revistas.unal.edu.co/index.php/dyna/article/view/26012
dc.relation.ispartofUniversidad Nacional de Colombia Revistas electrónicas UN Dyna
dc.relation.ispartofDyna
dc.relation.ispartofseriesDyna; Vol. 78, núm. 168 (2011); 81-89 DYNA; Vol. 78, núm. 168 (2011); 81-89 2346-2183 0012-7353
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.titleExergoeconomic comparison of absorption refrigeration systems including a hibrid absorption-ejecto compression chiller
dc.typeArtículo de revista
dc.type.driverinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/28079/
dc.relation.referencesBurbano Jaramillo, Juan Carlos and Pellegrini, Luiz Felipe and de Oliveira Jr., Silvio (2011) Exergoeconomic comparison of absorption refrigeration systems including a hibrid absorption-ejecto compression chiller. Dyna; Vol. 78, núm. 168 (2011); 81-89 DYNA; Vol. 78, núm. 168 (2011); 81-89 2346-2183 0012-7353 .
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalHybrid refrigeration system
dc.subject.proposalabsorption ejecto-compression chiller
dc.subject.proposalexergoeconomic analysis
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial 4.0 InternacionalThis work is licensed under a Creative Commons Reconocimiento-NoComercial 4.0.This document has been deposited by the author (s) under the following certificate of deposit