Show simple item record

dc.rights.licenseAtribución-NoComercial 4.0 Internacional
dc.contributor.authorOsorio Saraz, Jairo Alexander
dc.contributor.authorFerreira Tinôco, Ilda de Fátima
dc.contributor.authorOliveira Rocha, Keller Sullivan
dc.contributor.authorArêdes Martins, Marcio
dc.contributor.authorOliveira de Paula, Marcos
dc.date.accessioned2019-06-28T09:34:04Z
dc.date.available2019-06-28T09:34:04Z
dc.date.issued2011
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/40463
dc.description.abstractThe aim of this study was to develop and validate a simplified steady state mathematical model to predict temperature distribution in a commercial poultry house equipped with a negative pressure ventilation system and internal misting. The model was validated with data obtained experimentally during the summer. For external temperature conditions of 26, 27, and 29 °C, the best combinations of energy generated by misting (qmisting), ventilation rate (V), global heat loss coefficient for the roof (Ut), and global heat loss coefficient for the wall (Upar) were encountered to maintain the majority of the installation with temperatures within the optimal thermal comfort range for the birds (24 to 29 °C).
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia Sede Medellín
dc.relationhttp://revistas.unal.edu.co/index.php/dyna/article/view/29400
dc.relation.ispartofUniversidad Nacional de Colombia Revistas electrónicas UN Dyna
dc.relation.ispartofDyna
dc.relation.ispartofseriesDyna; Vol. 78, núm. 170 (2011); 167-174 DYNA; Vol. 78, núm. 170 (2011); 167-174 2346-2183 0012-7353
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.titleModeling and experimental validation to estimate the energy balance for a poultry house with misting cooling
dc.typeArtículo de revista
dc.type.driverinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/30560/
dc.relation.referencesOsorio Saraz, Jairo Alexander and Ferreira Tinôco, Ilda de Fátima and Oliveira Rocha, Keller Sullivan and Arêdes Martins, Marcio and Oliveira de Paula, Marcos (2011) Modeling and experimental validation to estimate the energy balance for a poultry house with misting cooling. Dyna; Vol. 78, núm. 170 (2011); 167-174 DYNA; Vol. 78, núm. 170 (2011); 167-174 2346-2183 0012-7353 .
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalevaporative cooling
dc.subject.proposalthermal modeling
dc.subject.proposaltunnel ventilation broiler house
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial 4.0 InternacionalThis work is licensed under a Creative Commons Reconocimiento-NoComercial 4.0.This document has been deposited by the author (s) under the following certificate of deposit