Show simple item record

dc.rights.licenseAtribución-NoComercial 4.0 Internacional
dc.contributor.authorPérez-Ceballos, Ana María
dc.contributor.authorCalderón-Gutierrez, Jorge Andres
dc.contributor.authorRosa-Mattos, Oscar
dc.date.accessioned2019-06-29T10:20:58Z
dc.date.available2019-06-29T10:20:58Z
dc.date.issued2014-10-24
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/50489
dc.description.abstractThe influence of an electrolyte flux injection over the detection side on pure iron membranes on electrochemical hydrogen permeation test was studied. A modified Devanathan´s cell was used in the experiments. This cell allows the injection of an electrolyte flux over the hydrogen exit side during the permeation tests. In the hydrogen generation compartment a NaOH 0.1M + 2mgL-1 As2O3 solution was used applying a constant current of 2.85 mA. The detection side was maintained under potentiostatic control at potential values in the passivity range for iron. The solution used in the exit compartment was a borate buffer (pH=8.4). It was not observed a significant variation of the permeation current when an electrolyte flow was injected on iron samples, however, a slightly raise both of the steady state of permeation current density and the calculated permeation parameters was observed in the tests in which an electrolyte flux was applied.
dc.description.abstractTSe ha estudiado el efecto de la aplicación de un flujo de electrolito sobre la superficie de detección de una membrana de hierro puro en ensayos de permeación electroquímica de hidrógeno. Para la realización de los ensayos se usó una celda del tipo Devanathan modificada, de tal manera que un flujo de electrolito fue inyectado directamente sobre la superficie de salida de hidrógeno. La generación de hidrógeno se realizó aplicando una corriente catódica de 2,85mA y se usó una solución de NaOH 0,1M + 2mgL-1 As2O3. La celda de detección fue mantenida bajo control potenciostático y se usó una solución buffer de borato de sodio (pH=8,4). No se observó una variación significativa de la corriente de permeación en los ensayos realizados aplicando flujo de electrolito; sin embargo, si se obtuvo un ligero aumento en la densidad de corriente de permeación estacionaria y en los parámetros de permeación calculados (Dap, tL y moles de hidrógeno emergentes) en las pruebas en las que se aplicó un flujo de electrolito.
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia Sede Medellín
dc.relationhttp://revistas.unal.edu.co/index.php/dyna/article/view/40960
dc.relation.ispartofUniversidad Nacional de Colombia Revistas electrónicas UN Dyna
dc.relation.ispartofDyna
dc.relation.ispartofseriesDyna; Vol. 81, núm. 187 (2014); 152-157 DYNA; Vol. 81, núm. 187 (2014); 152-157 2346-2183 0012-7353
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.titleEffect of an electrolyte flow on electrochemical hydrogen permeation
dc.typeArtículo de revista
dc.type.driverinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/44486/
dc.relation.referencesPérez-Ceballos, Ana María and Calderón-Gutierrez, Jorge Andres and Rosa-Mattos, Oscar (2014) Effect of an electrolyte flow on electrochemical hydrogen permeation. Dyna; Vol. 81, núm. 187 (2014); 152-157 DYNA; Vol. 81, núm. 187 (2014); 152-157 2346-2183 0012-7353 .
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalPermeación electroquímica de hidrógeno
dc.subject.proposalhierro puro
dc.subject.proposalcorrosión
dc.subject.proposalElectrochemical hydrogen permeation
dc.subject.proposalpure iron.
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial 4.0 InternacionalThis work is licensed under a Creative Commons Reconocimiento-NoComercial 4.0.This document has been deposited by the author (s) under the following certificate of deposit