dc.description.abstractIn this study, experimental investigations were carried out on polypropylene fiber (PF), steel mesh (SM) and PF+SMreinforced shotcrete (RS) panels to evaluate performance characteristics of energy absorption and load capacity. Inaddition to this, material cost evaluation of shotcrete mixtures for unit energy absorption and load capacity has been given.The panel tests, along with the European specification for sprayed concrete (EFNARC), were done on 18 prismaticspecimens having the same mix designs and were cured for 28 days but reinforced at varying fiber dosages. Testresults indicate that in terms of unit cost performance for PF, the best dosages were 2 kg/m³ and 5 kg/m³ respectively.When compared with SM, it was determined that PF is more expensive within the range of 37 - 53%. ResumenEn este estudio se realizaron investigaciones experimentales en fibras de polipropileno, en mallas de acero y en paneles de hormigón proyectado reforzados con fibra de polipropileno y con mallas de acero para evaluar las características de desempeño en absorción de energía y en capacidad de carga. Adicionalmente, se provee una evaluación del costo de materiales en mezlas de hormigón proyectado por unidad de absorción de energía y por capacidad de carga. Los exámenes en paneles, con las especificaciones europeas para hormigón proyectado (EFNARC, inglés), se realizaron en 18 muestras prismáticas con los mismos diseños de mezcla y se curaron por 28 días con refuerzos de diferentes dosis de fibras. Los resultados de la evaluación indican que, en términos de desempeño por unidad de costo para fibras de polipropileno, las mejores dosis fueron 2 kg/m3 y 5 kg/m3, respectivamente. Cuando se comparó con las mallas de acero, se determinó que las fibras de polipropileno son entre el 37 % y el 53 % más caras.
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Ciencias - Departamento de Geociencia
dc.relationhttps://revistas.unal.edu.co/index.php/esrj/article/view/40995
dc.relation.ispartofUniversidad Nacional de Colombia Revistas electrónicas UN Earth Sciences Research Journal
dc.relation.ispartofEarth Sciences Research Journal
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.ddc55 Ciencias de la tierra / Earth sciences and geology
dc.titleDetermining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
dc.typeArtículo de revista
dc.type.driverinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/64098/
dc.relation.referencesKahraman, Bayram (2015) Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications. Earth Sciences Research Journal, 19 (1). pp. 81-84. ISSN 2339-3459
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalShotcrete
dc.subject.proposalPolypropylene Fiber
dc.subject.proposalEnergy Absorption
dc.subject.proposalPanel test
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial 4.0 InternacionalThis work is licensed under a Creative Commons Reconocimiento-NoComercial 4.0.This document has been deposited by the author (s) under the following certificate of deposit