Show simple item record

dc.rights.licenseAtribución-NoComercial 4.0 Internacional
dc.contributor.advisorMolina Herrera, Maritzabel
dc.contributor.authorFuentes Parra, Gustavo Alonso
dc.date.accessioned2020-02-07T13:36:49Z
dc.date.available2020-02-07T13:36:49Z
dc.date.issued2020-02-06
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/75557
dc.description.abstractThe steel concrete composite beams is a system that a steel wide-flange shape (I or W shape) is attached to a concrete floor slab by shear connectors. The use of steel-concrete composite beams has been increased by the advantages it presents over other systems. In Colombia, the screws connectors grade two is frequently used in composite sections due to simple installation on site and easy acquirement. The experimental works about the behavior of composite sections with screw connectors have been shown that the connectors are subjected to combined effects of tension and shear in the inelastic range. Taking into account these, is necessary to analyze the behavior of the composite sections with screws connectors under tensile actions. In the present research, the behavior of composite sections had been analyzed when the screw connectors are subjected to tension actions. Pull-Out tests were performed on specimens composed of one screw embedded in concrete block. As variables were considered: the depth 2, 3 and 4 inches, and the diameter of the connector: 1/2", 5/8” and 3/4”, it defined 9 configurations to analyze and 3 specimens per configuration for a total of 27 tests. The 9 configurations of the exp erimental phase were simulated numerically in the ANSYS, finite element analysis program, in order to validate the numerical models with the behavior observed in the experimentation and analyze the failure mechanisms in concrete and the screw. Finally, comparisons were made between the behaviors obtained by experimentation and numerical simulation with the guidelines specified in the current regulations (NSR-10).
dc.description.abstractEl sistema de sección compuesta de vigas de acero y losas de concreto unidas por conectores de cortante se ha incrementado por las ventajas que presenta ante otros sistemas de entrepiso. En Colombia uno de los conectores comúnmente usados son los tornillos grado dos en las secciones compuestas debido a su facilidad de instalación en obra y fácil adquisición. En los estudios experimentales de secciones compuestas con conectores tipo tornillo bajo ensayos de corte directo se ha evidenciado que los conectores en el rango inelástico trabajan bajo la acción combinada de esfuerzos cortantes y de tensión. Esto evidencia la necesidad de analizar el comportamiento de las secciones compuestas con este tipo de conectores ante solicitaciones únicamente de tracción. En el presente trabajo de investigación se analizó el comportamiento de secciones compuestas cuando los conectores tipo tornillo se someten a cargas de tensión, para ello se realizaron ensayos tipo Pull-Out sobre probetas conformadas por un tornillo grado dos embebido en una matriz de concreto. Como variables de estudio se consideraron la profundidad: 2, 3 y 4 pulgadas, y el diámetro del conector: 1/2, 5/8 y 3/4 de pulgada, para un total de 9 configuraciones de estudio, de las cuales se ensayaron 3 probetas por cada configuración para un total de 27 ensayos. Asimismo se simularon numéricamente las 9 configuraciones de la fase experimental, en el programa de análisis por elementos finitos ANSYS, esto con el objeto de validar los modelos numéricos con el comportamiento observado en la experimentación y analizar localmente los mecanismos de falla en el concreto y el tornillo. Finalmente se realizaron comparaciones entre los comportamientos obtenidos de manera experimental y los obtenidos mediante la modelación numérica con respecto a los lineamientos estipulados en la normatividad actual (NSR-10) de las secciones compuestas con conectores de cortante tipo tornillo bajo las cargas a tracción.
dc.format.extent185
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.ddcIngeniería y operaciones afines
dc.titleAnálisis del desprendimiento del concreto en conectores de cortante tipo tornillo sometidos a tracción
dc.typeOtro
dc.rights.spaAcceso abierto
dc.description.additionalMagíster en Ingeniería - Estructuras. Línea de Investigación: Análisis y Diseño Estructural.
dc.type.driverinfo:eu-repo/semantics/other
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dc.description.degreelevelMaestría
dc.publisher.branchUniversidad Nacional de Colombia - Sede Bogotá
dc.relation.referencesAIS, A. C. de I. S. (2010). NSR10 - Titulo C: Concreto estructural. Reglamento Colombiano De Construcción Sismo Resistente Nsr-10. ANSYS Inc. (2013). ANSYS Mechanical APDL Documentation. ANSYS Manual. https://doi.org/www.ansys.com Erazo, L. (2017). Comportamiento de Conectores de Cortante Tipo Tornillo en Secciones Compuestas con Lámina Colaborante. Universidad Nacional de Colombia. Garcia, A., & Molina, M. (2008). Comportamiento de vigas de sección compuesta con perfiles de acero laminado y losa de concreto empleando conectores de cortante tipo tornillo grado dos (2), 28(3), 11–21. Gere, J. M., & Goodno, B. J. (2009). Mecánica de materiales. (Cengage Learning Editores SA, Ed.) (Séptima). Mexico D.F. Hurtado, X. F., & Molina, M. (2011). Formulación para el diseño de conectores de cortante tipo tornillo en secciones compuestas. Ingeniería e Investigación, 31(2), 52– 64. Hurtado, X. F., Molina, M., & Linero, D. (2008). Comportamiento de conectores de cortante tipo tornillo de resistencia grado dos para un sistema de sección compuesta Grade-two. Ingeniería e Investigación, 28(2), 4–14. Krishnan, P. D. and S. (1964). Equation for the Stress-Strain Curve of Concrete. Journal Proceedings, 61(3). https://doi.org/10.14359/7785 Larrañaga, S., & Molina, M. (2007). Comportamiento de los conectores de cortante tipo tornillo de resistencia grado dos para una sección compuesta con concreto de 28 MPa. Ingeniería e Investigación, 27(2), 18–25. Mccormac, J. C., & Brown, R. H. (2011). DISEÑO DE CONCRETO REFORZADO. (Alfaomega Grupo Editor SA, Ed.) (Octava). Mexico D.F. Mccormac, J. C., & Csernak, S. F. (2013). Diseño De Estructuras De Acero. (Alfaomega Grupo Editor SA, Ed.) (Quintai). Mexico D.F. Retrieved from http://www.alfaomega.com.mx Ollgaard, J. G.; Slutter, R. G.; Fisher, J. W. (1971). Shear strength of stud connectors in lightweight and normal weight concrete, AISC Eng’g Jr., April 1971 (71-10). AISC Engineering Journal, 1971(April 1971), 55–34. Pallarés, L., & Hajjar, J. F. (2010). Headed steel stud anchors in composite structures, Part II: Tension and interaction. Journal of Constructional Steel Research, 66(2), 213–228. https://doi.org/10.1016/j.jcsr.2009.08.008 Rivera Aguirre, J. I. (2012). Simulación Numérica del Comportamiento de Conectores de Cortante Tipo Tornillo en un Sistema de Sección Compuesta ante Solicitación de Corte Directo. Universidad Nacional de Colombia. Retrieved from http://www.bdigital.unal.edu.co/9008/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalPull-out test; Numerical modeling; Composite section; Screw
dc.subject.proposalEnsayo pull-out; Modelación numérica; Sección compuesta; Tornillo
dc.type.coarhttp://purl.org/coar/resource_type/c_1843
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.contentText
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial 4.0 InternacionalThis work is licensed under a Creative Commons Reconocimiento-NoComercial 4.0.This document has been deposited by the author (s) under the following certificate of deposit