Mostrar el registro sencillo del documento

dc.rights.licenseAtribución-NoComercial 4.0 Internacional
dc.contributorValencia Valencia, Doris
dc.contributor.authorMora Caro, Luis Mauricio
dc.date.accessioned2019-06-29T14:00:39Z
dc.date.available2019-06-29T14:00:39Z
dc.date.issued2015
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/52306
dc.description.abstractSe presenta la experiencia inicial en el diagnóstico precoz de hipoacusia neonatal en 423 pacientes de 4 hospitales de Bogotá, en un período entre el 2008 y el 2014. Se realizó prueba inicial y confirmatoria en un total de 211 pacientes para detectar hipoacusia. Se realizó consentimiento informado a los participantes del estudio. El objetivo es determinar el porcentaje de daño auditivo de la población atendida en cuatro hospitales de Bogotá mediante emisiones otoacústicas con el objetivo de implementar detección temprana e inicio oportuno de rehabilitación auditiva. Tipo de estudio. Estudio de longitudinal, descriptivo, retrospectivo y prospectivo, en donde se realizaron Emisiones Otoacústicas Transitorias a recién nacidos pretérmino y a término, la prueba de tamizaje se repitió nuevamente en 211 pacientes y se analizaron los resultados de la primera prueba con la segunda prueba y se correlacionaron los factores de riesgo para hipoacusia. De los 211 pacientes a los que se les realizo la primera prueba, 145 la pasaron y 66 no la pasaron. De estos 145 pacientes, 141 pacientes pasaron la segunda prueba, lo que representa una probabilidad del 0.97 de confiabilidad en las otoemisiones acústicas para valorar integridad de la vía auditiva hasta la cóclea, con lo cual si el paciente pasa el primer tamizaje, no se hace necesario repetir una segunda prueba. La probabilidad que un paciente pase la prueba dado que tuvo resultado positivo en la prueba Cocleopalpebral es de 0.62. No se encontró correlación significativa con los factores de riesgo estudiados para la prueba positiva de hipoacusia. El estudio sugiere que el tamizaje auditivo con Otoemisiones acústicas es un método confiable para la deteccion temprana de hipoacusia en pacientes en la primera infancia, su diagnóstico temprano permite la implementación de programas de rehabilitación de forma oportuna. Este metodo de tamizaje deberia realizarse de forma universal a todos los neonatos sin importar si presentan o no factores de riesgo para hipoacusia.
dc.description.abstractAbstract. We present our initial experience in the early diagnosis of neonatal hearing loss in 423 patients 4 hospitals in Bogotá, in a period between 2008 and 2014. Initial and confirmatory test was performed in a total of 211 patients to detect hearing impairment. Informed consent of the study participants was conducted. The objective is to determine the percentage of hearing impairment of the population served in four hospitals in Bogotá by otoacoustic emissions in order to implement early detection and timely start hearing rehabilitation. Type of study. Longitudinal study, descriptive, retrospective and prospective, where Transient Otoacoustic Emissions were performed at preterm and term screening test was repeated again in 211 patients and the results of the first test with the second test were analyzed and corelacionaron risk factors for hearing loss. Of the 211 patients who underwent the first test, 145 passed it and 66 not passed. Of these 145 patients, 141 patients underwent the second test, which represents a probability of 0.97 of reliability otoacoustic emissions to assess integrity of the auditory pathway to the cochlea, which if the patient passes the first screening is not be repeated a second test. The probability that a patient passes the test since had a positive result on the test cocleopalpebral is 0.62. No significant correlation with risk factors studied for positive test hearing loss was found. The study suggests that hearing screening with Otoacoustic Emissions is a reliable method for early detection of hearing loss in patients in early childhood, his early diagnosis allows the implementation of rehabilitation programs in a timely manner. This method of screening should be performed universally to all infants regardless of whether or not present risk factors for hearing loss.
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.relation.ispartofUniversidad Nacional de Colombia Sede Bogotá Facultad de Medicina Departamento de Medicina Física y Rehabilitacion
dc.relation.ispartofDepartamento de Medicina Física y Rehabilitacion
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.ddc51 Matemáticas / Mathematics
dc.subject.ddc61 Ciencias médicas; Medicina / Medicine and health
dc.titleTamizaje auditivo en niños con alto riesgo de hipoacusia
dc.typeTrabajo de grado - Pregrado
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/46633/
dc.description.degreelevelOtra
dc.relation.referencesMora Caro, Luis Mauricio (2015) Tamizaje auditivo en niños con alto riesgo de hipoacusia. Otra thesis, Universidad Nacional de Colombia.
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalHipoacusia
dc.subject.proposalOtoemisiones acústicas
dc.subject.proposalTamizaje
dc.subject.proposalRehabilitación auditiva
dc.subject.proposalReflejo cocleopalpebral
dc.subject.proposalHearing loss
dc.subject.proposalOtoacoustic Emissions
dc.subject.proposalScreening
dc.subject.proposalHearing rehabilitation
dc.subject.proposalCochleopalpebral reflex
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/TP
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Archivos en el documento

Thumbnail

Este documento aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del documento

Atribución-NoComercial 4.0 InternacionalEsta obra está bajo licencia internacional Creative Commons Reconocimiento-NoComercial 4.0.Este documento ha sido depositado por parte de el(los) autor(es) bajo la siguiente constancia de depósito