Mostrar el registro sencillo del documento
Colonización bacteriana de la interfase implante-pilar en implantes de conexión interna sometidos a carga dinámica con pilares personalizados
dc.rights.license | Atribución-NoComercial 4.0 Internacional |
dc.contributor | Sarmiento Delgado, Martha Lucia |
dc.contributor.advisor | Serrano Mendez, Carlos Alberto (Thesis advisor) |
dc.contributor.advisor | Henao Riveros, Sandra Consuelo (Thesis advisor) |
dc.contributor.author | Buitrago Osuna, Asterlis |
dc.date.accessioned | 2019-07-02T11:25:29Z |
dc.date.available | 2019-07-02T11:25:29Z |
dc.date.issued | 2015 |
dc.identifier.uri | https://repositorio.unal.edu.co/handle/unal/55686 |
dc.description.abstract | La interfase implante pilar es un punto crítico, por su importancia desde el punto de vista biomecánico y biológico. Esta zona, da lugar a la formación de un espacio en cercanía a los tejidos peri implantares, en el cual se presenta colonización de microorganismos (bacteria y hongos), que migran de manera bidireccional a través de ella y que eventualmente pueden generar activación de mecanismos inmunológicos que pueden desencadenar pérdida ósea. Debido a lo anterior surge este trabajo, cuya finalidad es evaluar la colonización bacteriana en la interfase implante-pilar en implantes de conexión interna con pilares personalizados. Materiales y métodos: Se estudiaron tres grupos cada uno con tres implantes de conexión interna hexagonal, con pilares en titanio prefabricados y personalizados, y pilares en zirconia personalizados, que fueron sometidos a carga dinámica in vitro. Se realizaron mediciones del tamaño de la interfase implante-pilar mediante microscopia electrónica de barrido (MEB), y se evaluó la filtración de bacterias, utilizando la bacteria E.coli y valorando la filtración de afuera hacia adentro mediante espectrofotometría. Resultados: se encontró que todos los implantes permitieron la filtración de bacterias, no mostró correlación entre el tamaño de la interfase y la absorbancia. |
dc.description.abstract | Abstract. The implant-abutment interface is a critic point, because of its relevance from the biomechanical and biologic point of view. This site favores the formation of a gap close to the peri-implant tissues, where there is a colonization by microorganisms (bacteria and fungi), that migrate bidirectionally across the gap and eventually induce activation of immunological mechanisms that can promote bone loss. The aim of this study is, evaluate the bacterial colonization of implant-abutment interface in implants with internal hex connection using personalized abutment. Materials and methods: Three groups were studied, each on with three Implants with internal hex with prefabricated and personalized titanium abutments and personalized zirconia abutments. They were placed under in-vitro dynamic loading. The size of the implant-abutment gap was measured with scanning electron microscopy, and the bacteria filtration was evaluated using E. coli to measure the filtration outside- inside using spectrophotometry Results: the bacterial filtration was found in all of implants evaluated. No positive correlation was found between the size of the interface and the absorbance. |
dc.format.mimetype | application/pdf |
dc.language.iso | spa |
dc.relation.ispartof | Universidad Nacional de Colombia Sede Bogotá Facultad de Odontología |
dc.relation.ispartof | Facultad de Odontología |
dc.rights | Derechos reservados - Universidad Nacional de Colombia |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ |
dc.subject.ddc | 61 Ciencias médicas; Medicina / Medicine and health |
dc.title | Colonización bacteriana de la interfase implante-pilar en implantes de conexión interna sometidos a carga dinámica con pilares personalizados |
dc.type | Trabajo de grado - Pregrado |
dc.type.driver | info:eu-repo/semantics/bachelorThesis |
dc.type.version | info:eu-repo/semantics/acceptedVersion |
dc.identifier.eprints | http://bdigital.unal.edu.co/51129/ |
dc.description.degreelevel | Otra |
dc.relation.references | Buitrago Osuna, Asterlis (2015) Colonización bacteriana de la interfase implante-pilar en implantes de conexión interna sometidos a carga dinámica con pilares personalizados. Otra thesis, Universidad Nacional de Colombia - Sede Bogotá. |
dc.rights.accessrights | info:eu-repo/semantics/openAccess |
dc.subject.proposal | Carga bacteriana |
dc.subject.proposal | Implantes dentales |
dc.subject.proposal | Interfase implante- pilar |
dc.subject.proposal | Titanio |
dc.subject.proposal | Microbiología |
dc.subject.proposal | CAD/CAM |
dc.subject.proposal | Bacterial load |
dc.subject.proposal | Dental implants |
dc.subject.proposal | Dental Implant-Abutment Interface |
dc.subject.proposal | Titanium |
dc.subject.proposal | microbiology |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f |
dc.type.coarversion | http://purl.org/coar/version/c_ab4af688f83e57aa |
dc.type.content | Text |
dc.type.redcol | http://purl.org/redcol/resource_type/TP |
oaire.accessrights | http://purl.org/coar/access_right/c_abf2 |
Archivos en el documento
Este documento aparece en la(s) siguiente(s) colección(ones)
-
Odontología [141]
![Atribución-NoComercial 4.0 Internacional](/themes/Mirage2//images/creativecommons/cc-generic.png)