dc.description.abstractHuman movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sensor-based portable electrogoniometer aimed at measuring joint range of motion. The system is composed of two inertial measurement units and a microcontroller that permits real-time human motion capture. The electrogoniometer was tested both in static and dynamic conditions in comparison to a standard commercial electrogoniometer during elbow movements. For static validation, the concordance correlation coefficient (ρC) obtained was 0.9605. The ρC found for slow-speed cyclical movements was 0.9830 and the ρC found for moderate-speed cyclical movements was 0.9619.
dc.description.abstractEl análisis del movimiento humano ha llegado a ser fundamental para una amplia gama de aplicaciones, tales como terapias físicas, neuro-rehabilitación, medicina deportiva, la evaluación de la funcionalidad del sistema motor y la medicina del trabajo. Este artículo se centra en el diseño, implementación y validación de un electrogoniómetro portátil basado en sensores inerciales y magnéticos para la adquisición del rango articular de movimiento. El sistema se compone de dos unidades de medición inercial y un microcontrolador que permite la captura de movimiento humano en tiempo real. El electrogoniómetro se validó tanto en condiciones estáticas como dinámicas, en comparación con un electrogoniómetro estándar comercial para movimientos de la articulación del codo. Para validación estática, el coeficiente de correlación de concordancia (ρC) obtenido fue 0.9605. El ρC obtenido para los movimientos cíclicos de baja velocidad fue 0.9830 y el ρC obtenido para los movimientos cíclicos de velocidad moderada fue 0.9619.
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.
dc.relationhttps://revistas.unal.edu.co/index.php/dyna/article/view/59054
dc.relation.ispartofUniversidad Nacional de Colombia Revistas electrónicas UN Dyna
dc.relation.ispartofDyna
dc.rightsDerechos reservados - Universidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.ddc62 Ingeniería y operaciones afines / Engineering
dc.titleWearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
dc.typeArtículo de revista
dc.type.driverinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.eprintshttp://bdigital.unal.edu.co/58728/
dc.relation.referencesRuiz-Olaya, Andrés F. and Callejas-Cuervo, Mauro and Lara-Herrera, Claudia N. (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion. DYNA, 84 (201). pp. 180-185. ISSN 2346-2183
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.proposalElectrogoniometer
dc.subject.proposalinertial sensors
dc.subject.proposaljoint range of motion
dc.subject.proposalmotion capture system
dc.subject.proposalElectrogoniómetro
dc.subject.proposalsensores inerciales
dc.subject.proposalrango articular de movimiento
dc.subject.proposalsistema de captura de movimiento
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/ART
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Archivos en el documento

Thumbnail

Este documento aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del documento

Atribución-NoComercial 4.0 InternacionalEsta obra está bajo licencia internacional Creative Commons Reconocimiento-NoComercial 4.0.Este documento ha sido depositado por parte de el(los) autor(es) bajo la siguiente constancia de depósito