dc.description.abstractIn nuclear medicine and radiopharmacy, the measurement of radiopharmaceutical radioactivities using dose calibrators (ionization chambers) constitutes a daily practice. These measurements are essential to know the amount of radioactive material applied to radionuclide therapy patients and those having diagnostic support images taken. Using the results of quality controls, we evaluate the performance of a group of dose calibrators that belongs to the Instituto Nacional de Cancerología (INC). We designed and implemented testing protocols to statistically assess the annual performance of dose calibrators, including geometries of clinical interest, the time evolution of daily radioactive measurements during a year, radiophar- maceutical varieties, etc. As additional outcomes, we performed and reported an upgraded energy and efficiency calibration of the Well-Type NaI(Tl) scintillation detector of the INC. We also estimated reference levels of administered activities for diagnostic images in PET (Positron Emission Tomography).
dc.description.abstractLa medición de actividad radiactiva de radiofármacos usando activímetros (cámaras de ionización) constituye una práctica del quehacer cotidiano en medicina nuclear y radiofarmacia. Estas mediciones son esenciales para conocer la cantidad de material radiactivo inyectado a pacientes en terapia con radionucleidos y a aquellos que se les toman imágenes de apoyo diagnóstico. En esta tesis se evaluó el desempeño de un grupo de activímetros del Instituto Nacional de Cancerología (INC) usando como base resultados de controles de calidad allí realizados. Para esto, se diseñaron e implementaron protocolos de prueba para la evaluación estadística del desempeño diario y anual de esos activímetros. Estas pruebas se enfocaron en evaluar la relación entre las medidas de los activímetros con una diversidad de geometrías y radiofármacos de interés clínico (y con otros parámetros de control), y en caracterizar la evolución temporal de medidas radiactivas diarias a lo largo de un año. Como resultados adicionales, se realizó una calibración actualizada (en energía y eficiencia) del detector centellador (tipo pozo) de NaI(Tl) perteneciente al INC y se estimaron niveles de referencia de actividades suministradas a pacientes que requerían imágenes diagnósticas tipo PET (Positron Emission Tomography).
dc.format.extentXV, 80 páginas
dc.format.mimetypeapplication/pdf
dc.language.isospa
dc.publisherUniversidad Nacional de Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc530 - Física::535 - Luz y radiación relacionada
dc.titleEvaluación de las incertidumbres asociadas con la medición de actividad de radiofármacos
dc.typeTrabajo de grado - Maestría
dc.type.driverinfo:eu-repo/semantics/masterThesis
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dc.publisher.programBogotá - Ciencias - Maestría en Física Médica
dc.description.degreelevelMaestría
dc.description.degreenameMagister en Física Médica
dc.identifier.instnameUniversidad Nacional de Colombia
dc.identifier.reponameRepositorio Institucional Universidad Nacional de Colombia
dc.identifier.repourlhttps://repositorio.unal.edu.co/
dc.publisher.departmentDepartamento de Física
dc.publisher.facultyFacultad de Ciencias
dc.publisher.placeBogotá, Colombia
dc.publisher.branchUniversidad Nacional de Colombia - Sede Bogotá
dc.relation.referencesReport 90. En: Journal of the International Commission on Radiation Units and Measurements 14 (2016), 10, Nr. 1. – ISSN 1473–6691 

dc.relation.referencesLa PET/TC con 68Ga-PSMA en el cáncer de próstata. En: Revista Española de Medicina Nuclear e Imagen Molecular 37 (2018), p. 130–138 

dc.relation.referencesAgency, International Atomic E.: Quality Assurance for Radioactivity Measurement in Nuclear Medicine. International Atomic Energy Agency, 2006. – ISBN 920–105306–1 

dc.relation.referencesAlessio, Adam M. ; Farrell, Mary B. ; Fahey, Frederic H.: Role of Reference Levels in Nuclear Medicine: A Report of the SNMMI Dose Optimization Task Force. En: Journal of Nuclear Medicine 56 (2015), Nr. 12, p. 1960–1964. – ISSN 0161–5505 

dc.relation.referencesAndreo, P. ; Burns, D.T. ; Nahum, A.E. ; Seuntjens, J. ; Attix, F.H.: Fundamentals of Ionizing Radiation Dosimetry. Wiley, 2017. – ISBN 9783527409211 

dc.relation.referencesBerger, M.J. ; Hubbell, J.H. ; Seltzer, S.M. ; Chang, J. ; Coursey, J.S. ; Sukumar, R. ; Zucker, D.S. ; Olsen, K. XCOM: Photon Cross Section Database (version 1.5). National Institute of Standards and Technology. (2010) 

dc.relation.referencesCherry, S.R. ; Sorenson, J.A. ; Phelps, M.E.: Physics in Nuclear Medi- cine. Saunders, 2003. – ISBN 9780721683416 

dc.relation.referencesChu, R.Y.L. ; Simon, W.E: Quality Control Testing of Dose Calibrators. En: Journal of Nuclear Medicine Technology 24 (1996), p. 124–128 
  
dc.relation.referencesCristancho, F. ; Fajardo, F. Física Experimental II (Mecánica e introducción a la física térmica), Notas de Clase. Agosto 2003 

dc.relation.referencesCristancho, L. Instrumentación Nuclear, Notas de Clase. Agosto 2013 

dc.relation.referencesInstitute, American National S.: Calibration and usage of “dose calibra- tor” ionization chambers for the assay of radionuclides. American National Standards Institute, 2004
dc.relation.referencesJackson, John D.: Classical electrodynamics. John Wiley & Son, 1999. – ISBN 0–471–30932
dc.relation.referencesKnoll, Glenn F.: Radiation detection and measurement. John Wiley & Son, 2010. – ISBN 978–0–470–13148–0 

dc.relation.referencesLaboratory, National P. Course: Radionuclide calibrator, Module 1: How a radionuclide calibrator works 

dc.relation.referencesLaboratory, National P. Course: Understanding Uncertainty Budgets, Module 1: Creating a simple uncertainty budget 

dc.relation.referencesLeo, William R.: Techniques for Nuclear and Particle Physics Experiments. Springer-Verlag Berlin Heidelberg, 1994. – ISBN 978–3–540–57280–0 

dc.relation.referencesMarkets ; Markets. Nuclear Medicine/Radiopharmaceuticals Market 

dc.relation.referencesMarquez Miranda, P.: Diseño de protocolos en control de calidad de medicina nuclear en una IPS de alta complejidad de Bogotá, Universidad Nacional de Colombia Sede Bogotá Facultad de Ciencias Departamento de Física, Tesis de Grado, 2019 

dc.relation.referencesMartí, A.: Tumor neuroendocrino estadificado con galio68-tomografía por emisión de positrones/tomografía computarizada. En: Revista Colombiana de Cancerología 18 (2014), p. 46–49 

dc.relation.referencesUse of byproduct material, Medical: U.S. Nuclear Regulatory Commission. Medical use of byproduct material, 2007 (Title 10 Code of Federal Regulations Part 35) 

dc.relation.referencesof Physicists in Medicine, American A.: The Selection, Use, Calibration, and Quality Assurance of Radionuclide Calibrators Used in Nuclear Medicine. American Association of Physicists in Medicine, 2012 (Report of AAPM Task Group 181). – ISBN 978–1–936366–18–7 

dc.relation.referencesP.Maltby: Radiopharmacy quality control. 2009. Berlin: Liverpool (UK), 2009 (consultado Diciembre 7, 2020) 

dc.relation.referencesTaylor, J.R.: An introduction to error analysis. University Science Book, 1997. – ISBN 0–935702–42–3 

dc.relation.referencesVargas, J.A.: Control Estadístico de Calidad. Bogotá: Universidad Nacional de Colombia. Facultad de Ciencias, 2006. – ISBN 958–701–725–0
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.subject.lembRadiología médica- aparatos e instrumentos
dc.subject.lembRadiology, medical - instruments
dc.subject.proposalMedicina nuclear
dc.subject.proposalRadiofarmacia
dc.subject.proposalActivímetro
dc.subject.proposalControl
dc.subject.proposalNuclear Medicine
dc.subject.proposalRadiopharmacy
dc.subject.proposalQuality Control
dc.title.translatedAssessment of uncertainties associated with the measurement of radiopharmaceutical activity
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.contentText
dc.type.redcolhttp://purl.org/redcol/resource_type/TM
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2


Archivos en el documento

Thumbnail
Thumbnail

Este documento aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del documento

Atribución-NoComercial 4.0 InternacionalEsta obra está bajo licencia internacional Creative Commons Reconocimiento-NoComercial 4.0.Este documento ha sido depositado por parte de el(los) autor(es) bajo la siguiente constancia de depósito