Establecimiento de un programa de control de calidad en mamografía digital
| dc.contributor.advisor | Daza Moreno, José Agustín | spa |
| dc.contributor.advisor | Plazas de Pinzón, María Cristina | spa |
| dc.contributor.author | Blanco Pacheco, Claudia Aracely | spa |
| dc.date.accessioned | 2020-09-16T15:39:35Z | spa |
| dc.date.available | 2020-09-16T15:39:35Z | spa |
| dc.date.issued | 2017-06-16 | spa |
| dc.description.abstract | In the medical field, diagnostic images play an important role in the early detection of various pathologies that, when detected in a timely manner, contribute to the prognosis; however, achieve accurate high-quality images of equipment operating under optimal conditions; this requires regular quality checks on the equipment with which the images are acquired. Taking into account the foregoing, this document presents the establishment of a quality control program implemented by to digital mammogram of the Santa Fe Foundation in Bogotá, based on the verification of mammography quality control protocols such as the American College of Radiology, International Atomic Energy Agency, Spanish Protocol and equipment manufacturer; In the execution of this program, geometric parameters, beam quality, dose, image visualization, automatic exposure control, among others, were evaluated. Some of the elements used to perform the tests were: ionization chamber, phantom (physical simulator) for mammography, resolution pattern and luxometer, after performing the tests satisfactory results were obtained according to the tolerances established by the manufacturer; In the same way, the adequate and optimal functioning of the equipment was evidenced. The optimal results obtained after the establishment of this program allowed the accreditation in digital mammography to be achieved at the American College of Radiology (ACR). | spa |
| dc.description.abstract | En el ámbito médico las imágenes diagnósticas desempeñan un papel importante frente a la detección temprana de diversas patologías que al ser detectadas oportunamente contribuyen en los pronósticos. Sin embargo, alcanzar imágenes de alta calidad precisa de equipos que operen bajo óptimas condiciones; para ello se requiere realizar periódicos controles de calidad a los equipos con que se adquieren las imágenes. En el presente documento se da a conocer el establecimiento de un programa de control de calidad implementado a un mamógrafo digital de la Fundación Santa Fe de Bogotá a partir de la verificación de protocolos de control de calidad en mamografía como el del Colegio Americano de Radiología, Organismo Internacional de Energía Atómica, Protocolo Español y fabricante del equipo; en la ejecución de este programa se evaluaron parámetros geométricos, calidad del haz, dosis, visualización de imágenes, control automático de exposición, entre otros. Algunos de los elementos empleados para realizar las pruebas fueron: cámara de ionización, phantom (simulador físico) para mamografía, patrón de resolución y luxómetro, luego de efectuar las pruebas se obtuvieron resultados satisfactorios acorde a las tolerancias establecidas por el fabricante; de igual manera, se evidenció el adecuado y óptimo funcionamiento del equipo. Los resultados obtenidos tras el establecimiento de este programa permitieron que se alcanzará la acreditación en mamografía digital con el Colegio Americano de Radiología (ACR). | spa |
| dc.description.degreelevel | Maestría | spa |
| dc.format.extent | 94 | spa |
| dc.format.mimetype | application/pdf | spa |
| dc.identifier.uri | https://repositorio.unal.edu.co/handle/unal/78467 | |
| dc.language.iso | spa | spa |
| dc.publisher.branch | Universidad Nacional de Colombia - Sede Bogotá | spa |
| dc.publisher.department | Departamento de Física | spa |
| dc.publisher.program | Bogotá - Ciencias - Maestría en Física Médica | spa |
| dc.relation.references | ACR. (1999). 1999 Mammography Quality Control Manual. American College of Radiology. | spa |
| dc.relation.references | Alejo M, Salazar E, Poveda C, Puerto D, Ramírez F, Roldán O. (2014). Impacto del programa de aseguramiento de la calidad de las mamografías en Colombia. Anales de Radiología México, 13:369-383. | spa |
| dc.relation.references | Alteri R., K. M. (2019). American Cancer Society. Obtenido de https://www.cancer.org/es/cancer/cancer-de-seno/pruebas-de-deteccion-y-deteccion-temprana-del-cancer-de-seno/mamogramas/conceptos-basicos-del-mamograma.html | spa |
| dc.relation.references | Álvarez, I. (s.f.). Rutina de mamografía. Obtenido de https://irmaalvarez.weebly.com/rutina-de-mamografia.html | spa |
| dc.relation.references | Baños, M. (2009). Lecciones de la Mamografía y sus Técnicas. Lección 4: El haz de radiación. Murcia, España. | spa |
| dc.relation.references | Baños, M. A., & Alegría, C. L. (2003). Bases físicas y biológicas del radiodiagnóstico médico. | spa |
| dc.relation.references | Barco. (11 de Septiembre de 2018). What to consider when buying a mammography display. Obtenido de https://www.barco.com/es/news/2018-09-11-what-to-consider-when-buying-a-mammography-display | spa |
| dc.relation.references | Berns E, B. J. (2016). Digital Mammography Quality Control Manual. American College of Radiology | spa |
| dc.relation.references | Díaz S., P. M. (2005). Detección temprana del cáncer de mama: aspectos críticos para un programa de tamizaje organizado en Colombia. Revista Colombiana de Cancerología | spa |
| dc.relation.references | FDA. (2017). Mamografías. Obtenido de https://www.fda.gov/media/106882/download | spa |
| dc.relation.references | Gaona. (2013). Optimización de los indicadores de calidad de imagen en mamografía analógica y digital (Doctoral dissertation). | spa |
| dc.relation.references | HOLOGIC. (2011). Quality Control Manual. Selenia Dimensions 2D FFDM. Selenia Dimensions DBT. | spa |
| dc.relation.references | HOLOGIC NV. (2010). Selenia Dimensions User Manual. Revision 001. | spa |
| dc.relation.references | IAEA. (2006). Control de Calidad en Mamografía, IAEA-TECDOC-1517, IAEA. Viena. | spa |
| dc.relation.references | IAEA. (2013). Protección radiológica de los pacientes. Obtenido de https://rpop.iaea.org/RPOP/RPoP/Content-es/InformationFor/HealthProfessionals/1_Radiology/Mammography/mammography-technique.htm#MFAQ08 | spa |
| dc.relation.references | IARC. (2018). Latest global cancer data: Cancer burden rises to 18.1 million new cases and 9.6 million cancer deaths in 2018. | spa |
| dc.relation.references | INC. (2013). Guía de práctica clínica (GPC) para la detección temprana, tratamiento integral, seguimiento y rehabilitación del cáncer de mama. BOGOTÁ, COLOMBIA. | spa |
| dc.relation.references | Instituto Nacional del Cáncer. (s.f.). Manual operativo para el uso de mamografía en tamizaje. Programa de Control de Cáncer de Mama. Aregentina. | spa |
| dc.relation.references | Kulama, E. (2009). Commissioning and routinetesting of full field nhsbsp Equipment Report 0604. London: NHS Cancer Screening Programmes. | spa |
| dc.relation.references | Luo M., L. F. (2019). Comparison of 21-gene assay and St.Gallen International Expert Consensus in the treatment decision for patients with early invasive breast cancers, Cancer Biology & Therapy. Cancer Biology & Therapy, 4. | spa |
| dc.relation.references | Martínez, X. R. (2012). Fundamentos de Física Médica Vol 2. Radiodiagnóstico: bases físicas, equipos y control de calidad. Madrid, Sociedad Española de Física Médica: ADI. | spa |
| dc.relation.references | MinSalud. (2019). Cáncer de mama. Obtenido de https://www.minsalud.gov.co/salud/publica/ssr/Paginas/Cancer-de-mama.aspx | spa |
| dc.relation.references | Morales, J. (2015). VI Congreso Nacional de Protección Radiológica: Radiología Convencional Digital. Obtenido de https://www.dssa.gov.co/index.php/descargas/1377-radiologia-convencional-a-digital/file | spa |
| dc.relation.references | NIH. (2019). National Cancer Institute. Obtenido de https://www.cancer.gov/types/breast/patient/breast-treatment-pdq#_125 | spa |
| dc.relation.references | OMS. (1984). Garantía de Calidad en Radiodiagnóstico. Publicación Científica N° 469. Ginebra. | spa |
| dc.relation.references | Palacios H., B. D. (2013). Imagenología de la mama. Obtenido de https://es.slideshare.net/alliepop73/imagenologa-de-mama?related=1 | spa |
| dc.relation.references | Pardo C, Cendales R. (2015). Incidencia, mortalidad y prevalencia de cáncer en Colombia, 2007 - 2011. Bogotá. D.C: Instituto Nacional de Cancerología. | spa |
| dc.relation.references | Perry, F; Garcia, , O; Diaz, , S; Guzman, , L; Ángel, , J; Lehmann, , C; Lehmann, , C; Peña, , E. (24 de Febrero de 2012). Guía de Práctica Clínica para la detección temprana, tratamiento integral, seguimiento y rehabilitación del Cáncer de Mama;. (I. N. ESE, Instituto Nacional de Cancerología; , Ministerio de Salud y Protección Social; , & Ministerio de Salud y Protección Social; , Edits.) | spa |
| dc.relation.references | Poveda., C. Arciniegas M. (2011). Control de calidad para los servicios de mamografía analógica. Programa para la detección temprana del cáncer de mama. Bogotá D.C: Instituto Nacional de Cancerología. | spa |
| dc.relation.references | RaySafe. (2018). RaySafe X2 User Manual. Unfors Raysafe. | spa |
| dc.relation.references | Salvador R., S. M. (2002). Mamografía digital de campo completo. Estudio comparativo con mamografía convencional. Revista de Senología y Patología Mamaria, 166 - 171. | spa |
| dc.relation.references | SEFM, S. S. (2012). Protocolo Epañol de Control de Calidad en Radiodiagnóstico. Madrid: Senda. | spa |
| dc.relation.references | Segui, Jennifer; Zhao, Wei. (2006). Amorphus selenium flat panel detectors for digital mammography: Validation of a NPEW model observer with CDMAM experiments. Medical physics., 33.3711-22.10.1118/1.2349689. | spa |
| dc.relation.references | Vergara M, S. G. (2006). Técnica radiográfica en radiografía computada. Revista Chilena de Radiología. Vol. 12 N° 4, 153-156. | spa |
| dc.relation.references | Weiss M. (2013). Breastcancer.org. Obtenido de https://www.breastcancer.org/es/sintomas/diagnostico/invasion_vascular_linfatico | spa |
| dc.relation.references | Yaffe M., M. A. (2014). Diagnostic Radiology Physics: A Handbook for Teachers and Students. En Diagnostic Radiology Physics: A Handbook for Teachers and Students (págs. 209 -239). Vienna: IAEA. | spa |
| dc.rights | Derechos reservados - Universidad Nacional de Colombia | spa |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 4.0 Internacional | spa |
| dc.rights.spa | Acceso abierto | spa |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | spa |
| dc.subject.ddc | 530 - Física | spa |
| dc.subject.proposal | Mamografía | spa |
| dc.subject.proposal | Mammography | eng |
| dc.subject.proposal | Quality control | eng |
| dc.subject.proposal | Control de calidad | spa |
| dc.subject.proposal | Phantom | eng |
| dc.subject.proposal | Phantom | spa |
| dc.subject.proposal | Calidad de imagen | spa |
| dc.subject.proposal | Image quality | eng |
| dc.subject.proposal | Radiation | eng |
| dc.subject.proposal | Radiación | spa |
| dc.subject.proposal | Doses | eng |
| dc.subject.proposal | Dosis | spa |
| dc.subject.proposal | Breast cancer | eng |
| dc.subject.proposal | Cáncer de mama | spa |
| dc.title | Establecimiento de un programa de control de calidad en mamografía digital | spa |
| dc.type | Trabajo de grado - Maestría | spa |
| dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | spa |
| dc.type.coarversion | http://purl.org/coar/version/c_ab4af688f83e57aa | spa |
| dc.type.content | Text | spa |
| dc.type.driver | info:eu-repo/semantics/masterThesis | spa |
| dc.type.version | info:eu-repo/semantics/acceptedVersion | spa |
| oaire.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- ESTABLECIMIENTO DE UN PROGRAMA DE CONTROL DE CALIDAD EN MAMOGRAFÍA DIGITAL.pdf
- Tamaño:
- 2.05 MB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 3.8 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: