Evaluación de las incertidumbres asociadas con la medición de actividad de radiofármacos

dc.contributor.advisorBarbosa Parada, Nathaly
dc.contributor.advisorVeloza Salcedo, Luz Stella
dc.contributor.authorLopez Rodriguez, Andrea Lizeth
dc.date.accessioned2021-08-26T18:03:00Z
dc.date.available2021-08-26T18:03:00Z
dc.date.issued2021
dc.description.abstractIn nuclear medicine and radiopharmacy, the measurement of radiopharmaceutical radioactivities using dose calibrators (ionization chambers) constitutes a daily practice. These measurements are essential to know the amount of radioactive material applied to radionuclide therapy patients and those having diagnostic support images taken. Using the results of quality controls, we evaluate the performance of a group of dose calibrators that belongs to the Instituto Nacional de Cancerología (INC). We designed and implemented testing protocols to statistically assess the annual performance of dose calibrators, including geometries of clinical interest, the time evolution of daily radioactive measurements during a year, radiophar- maceutical varieties, etc. As additional outcomes, we performed and reported an upgraded energy and efficiency calibration of the Well-Type NaI(Tl) scintillation detector of the INC. We also estimated reference levels of administered activities for diagnostic images in PET (Positron Emission Tomography).eng
dc.description.abstractLa medición de actividad radiactiva de radiofármacos usando activímetros (cámaras de ionización) constituye una práctica del quehacer cotidiano en medicina nuclear y radiofarmacia. Estas mediciones son esenciales para conocer la cantidad de material radiactivo inyectado a pacientes en terapia con radionucleidos y a aquellos que se les toman imágenes de apoyo diagnóstico. En esta tesis se evaluó el desempeño de un grupo de activímetros del Instituto Nacional de Cancerología (INC) usando como base resultados de controles de calidad allí realizados. Para esto, se diseñaron e implementaron protocolos de prueba para la evaluación estadística del desempeño diario y anual de esos activímetros. Estas pruebas se enfocaron en evaluar la relación entre las medidas de los activímetros con una diversidad de geometrías y radiofármacos de interés clínico (y con otros parámetros de control), y en caracterizar la evolución temporal de medidas radiactivas diarias a lo largo de un año. Como resultados adicionales, se realizó una calibración actualizada (en energía y eficiencia) del detector centellador (tipo pozo) de NaI(Tl) perteneciente al INC y se estimaron niveles de referencia de actividades suministradas a pacientes que requerían imágenes diagnósticas tipo PET (Positron Emission Tomography).spa
dc.description.degreelevelMaestríaspa
dc.description.degreenameMagister en Física Médicaspa
dc.format.extentXV, 80 páginasspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.instnameUniversidad Nacional de Colombiaspa
dc.identifier.reponameRepositorio Institucional Universidad Nacional de Colombiaspa
dc.identifier.repourlhttps://repositorio.unal.edu.co/spa
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/80032
dc.language.isospaspa
dc.publisherUniversidad Nacional de Colombiaspa
dc.publisher.branchUniversidad Nacional de Colombia - Sede Bogotáspa
dc.publisher.departmentDepartamento de Físicaspa
dc.publisher.facultyFacultad de Cienciasspa
dc.publisher.placeBogotá, Colombiaspa
dc.publisher.programBogotá - Ciencias - Maestría en Física Médicaspa
dc.relation.referencesReport 90. En: Journal of the International Commission on Radiation Units and Measurements 14 (2016), 10, Nr. 1. – ISSN 1473–6691 
spa
dc.relation.referencesLa PET/TC con 68Ga-PSMA en el cáncer de próstata. En: Revista Española de Medicina Nuclear e Imagen Molecular 37 (2018), p. 130–138 
spa
dc.relation.referencesAgency, International Atomic E.: Quality Assurance for Radioactivity Measurement in Nuclear Medicine. International Atomic Energy Agency, 2006. – ISBN 920–105306–1 
spa
dc.relation.referencesAlessio, Adam M. ; Farrell, Mary B. ; Fahey, Frederic H.: Role of Reference Levels in Nuclear Medicine: A Report of the SNMMI Dose Optimization Task Force. En: Journal of Nuclear Medicine 56 (2015), Nr. 12, p. 1960–1964. – ISSN 0161–5505 
spa
dc.relation.referencesAndreo, P. ; Burns, D.T. ; Nahum, A.E. ; Seuntjens, J. ; Attix, F.H.: Fundamentals of Ionizing Radiation Dosimetry. Wiley, 2017. – ISBN 9783527409211 
spa
dc.relation.referencesBerger, M.J. ; Hubbell, J.H. ; Seltzer, S.M. ; Chang, J. ; Coursey, J.S. ; Sukumar, R. ; Zucker, D.S. ; Olsen, K. XCOM: Photon Cross Section Database (version 1.5). National Institute of Standards and Technology. (2010) 
spa
dc.relation.referencesCherry, S.R. ; Sorenson, J.A. ; Phelps, M.E.: Physics in Nuclear Medi- cine. Saunders, 2003. – ISBN 9780721683416 
spa
dc.relation.referencesChu, R.Y.L. ; Simon, W.E: Quality Control Testing of Dose Calibrators. En: Journal of Nuclear Medicine Technology 24 (1996), p. 124–128 
  spa
dc.relation.referencesCristancho, F. ; Fajardo, F. Física Experimental II (Mecánica e introducción a la física térmica), Notas de Clase. Agosto 2003 
spa
dc.relation.referencesCristancho, L. Instrumentación Nuclear, Notas de Clase. Agosto 2013 
spa
dc.relation.referencesInstitute, American National S.: Calibration and usage of “dose calibra- tor” ionization chambers for the assay of radionuclides. American National Standards Institute, 2004spa
dc.relation.referencesJackson, John D.: Classical electrodynamics. John Wiley & Son, 1999. – ISBN 0–471–30932spa
dc.relation.referencesKnoll, Glenn F.: Radiation detection and measurement. John Wiley & Son, 2010. – ISBN 978–0–470–13148–0 
spa
dc.relation.referencesLaboratory, National P. Course: Radionuclide calibrator, Module 1: How a radionuclide calibrator works 
spa
dc.relation.referencesLaboratory, National P. Course: Understanding Uncertainty Budgets, Module 1: Creating a simple uncertainty budget 
spa
dc.relation.referencesLeo, William R.: Techniques for Nuclear and Particle Physics Experiments. Springer-Verlag Berlin Heidelberg, 1994. – ISBN 978–3–540–57280–0 
spa
dc.relation.referencesMarkets ; Markets. Nuclear Medicine/Radiopharmaceuticals Market 
spa
dc.relation.referencesMarquez Miranda, P.: Diseño de protocolos en control de calidad de medicina nuclear en una IPS de alta complejidad de Bogotá, Universidad Nacional de Colombia Sede Bogotá Facultad de Ciencias Departamento de Física, Tesis de Grado, 2019 
spa
dc.relation.referencesMartí, A.: Tumor neuroendocrino estadificado con galio68-tomografía por emisión de positrones/tomografía computarizada. En: Revista Colombiana de Cancerología 18 (2014), p. 46–49 
spa
dc.relation.referencesUse of byproduct material, Medical: U.S. Nuclear Regulatory Commission. Medical use of byproduct material, 2007 (Title 10 Code of Federal Regulations Part 35) 
spa
dc.relation.referencesof Physicists in Medicine, American A.: The Selection, Use, Calibration, and Quality Assurance of Radionuclide Calibrators Used in Nuclear Medicine. American Association of Physicists in Medicine, 2012 (Report of AAPM Task Group 181). – ISBN 978–1–936366–18–7 
spa
dc.relation.referencesP.Maltby: Radiopharmacy quality control. 2009. Berlin: Liverpool (UK), 2009 (consultado Diciembre 7, 2020) 
spa
dc.relation.referencesTaylor, J.R.: An introduction to error analysis. University Science Book, 1997. – ISBN 0–935702–42–3 
spa
dc.relation.referencesVargas, J.A.: Control Estadístico de Calidad. Bogotá: Universidad Nacional de Colombia. Facultad de Ciencias, 2006. – ISBN 958–701–725–0spa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.licenseAtribución-NoComercial 4.0 Internacionalspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.subject.ddc530 - Física::535 - Luz y radiación relacionadaspa
dc.subject.lembRadiología médica- aparatos e instrumentos
dc.subject.lembRadiology, medical - instruments
dc.subject.proposalMedicina nuclearspa
dc.subject.proposalRadiofarmaciaspa
dc.subject.proposalActivímetrospa
dc.subject.proposalControlspa
dc.subject.proposalNuclear Medicineeng
dc.subject.proposalRadiopharmacyeng
dc.subject.proposalQuality Controleng
dc.titleEvaluación de las incertidumbres asociadas con la medición de actividad de radiofármacosspa
dc.title.translatedAssessment of uncertainties associated with the measurement of radiopharmaceutical activityeng
dc.typeTrabajo de grado - Maestríaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_bdccspa
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/masterThesisspa
dc.type.redcolhttp://purl.org/redcol/resource_type/TMspa
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2spa

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Trabajogrado_Lopez_Rodriguez.pdf
Tamaño:
23.43 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
3.87 KB
Formato:
Item-specific license agreed upon to submission
Descripción: