Micro-filtración de bacterias en la interfase implante-pilar en implantes de conexión interna cónica sometidos a carga dinámica in-vitro

dc.contributorSarmiento Delgado, Martha Luciaspa
dc.contributorCastro Zarate, Maria Claudia Helenaspa
dc.contributorHenao Rivera, Sandra Consuelospa
dc.contributorCortes Rodriguez, Carlos Juliospa
dc.contributor.authorBuitrago Osuna, Asterlisspa
dc.date.accessioned2020-03-30T06:32:32Zspa
dc.date.available2020-03-30T06:32:32Zspa
dc.date.issued2019-03-01spa
dc.description.abstractLos implantes de dos componentes se utilizan con buenos porcentajes de éxito. Sin embargo, la interfase implante-pilar es una zona de alto riesgo de falla debido a que recibe parte del esfuerzo de la carga oclusal generando desajuste, micro-movimiento, aflojamiento y fractura del tornillo de fijación. Estos fenómenos pueden contribuir a la formación de un espacio que permite la movilización de bacterias hacia y desde dentro del implante. El tipo de conexión es el principal factor que influye en el comportamiento de la interfase, por tal motivo se ha evaluado la adaptación y capacidad de selle de conexiones internas y externas, siendo la conexión interna cónica aquella que demuestra mejores propiedades. De modo que, es relevante estudiar el comportamiento de las diferentes conexiones internas cónicas, dado que cada marca tiene particularidades geométricas que cambian sus propiedades. Por lo tanto, el objetivo de este estudio fue, evaluar la micro-filtración de Escherichia coli en la interfase implante-pilar de implantes de conexión interna cónica. Materiales y métodos: Para realizar la medición de la interfase implante-pilar (Δα) se utilizó el microscopio óptico de variación focal ALICONA. Para evaluar la filtración de bacterias en la interfase antes y después de carga, se sumergieron los complejos implante pilar de marca Ankylos y Neodent (N=5) en caldo BHI contaminado con E.coli, se tomaron muestras de la porción interna del implante y se evaluó la presencia de microorganismos utilizando cuatro metodologías diferentes. Los ensayos de carga cíclica se realizaron según la norma ISO 14801:2016. Resultados: El Δα de AN es 5,73º y de NE 5,82º. La filtración encontrada sin carga fué del 20% para el grupo NE y 0% para AN. Durante la carga, en el grupo AN aumentó a un 40%, mientras en NE disminuyó al 0%. Conclusiones: La interfase es menor en los implantes NE mientras es más precisa en los AN. Ninguna conexión fue capaz de impedir el paso e bacterias en el 100%.spa
dc.description.abstractAbstract: Internal conical connection implants have shown to be effective; however, the implant abutment connection is a high risk of failure area as it receives part of the effort coming from the occlusal load which, in turn, causes misfits, micro-movements, screw loosening and fracture. Such phenomena may contribute to the development of microgaps that allow the leakage of bacteria towards and from within the implant. The type of connection is the key factor that affects the interface behavior and that is why the adaptation and seal system of internal and external abutments have been thoroughly assessed. Internal conical connections have proved to have the best features. Hence the importance of studying the behavior of different internal conical connections, given the geometric specificities for each brand that, in turn, have a direct effect on their specific features. The aim of this study was to assess the outside-in micro-leakage of Escherichia coli at the implant-abutment (I-A) interface of different internal conical connection implants. Materials and methods: In order to assess the implant abutment interface (Δα), an ALICONA focus variation microscope was used to determine the bacteria leakage both under loaded and unloaded conditions. Some Ankylos and Neodent (N=5) abutments were submerged in Brain heart infusion broth (BHI) inoculated with Escherichia coli, afterwards, some samples were taken from the internal part of the implant by means of four different methodologies. The Cyclic load assays were performed in compliance with ISO 14801:2016.spa
dc.description.degreelevelMaestríaspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.eprintshttp://bdigital.unal.edu.co/73872/spa
dc.identifier.urihttps://repositorio.unal.edu.co/handle/unal/76900
dc.language.isospaspa
dc.relationhttp://www.scholarena.com/journals/journal-of-oral-health-and-dental-science/articles.php?volume=3 and issue=1spa
dc.relation.haspart57 Ciencias de la vida; Biología / Life sciences; biologyspa
dc.relation.haspart61 Ciencias médicas; Medicina / Medicine and healthspa
dc.relation.haspart62 Ingeniería y operaciones afines / Engineeringspa
dc.relation.haspart67 Manufactura / Manufacturingspa
dc.relation.ispartofUniversidad Nacional de Colombia Sede Bogotá Facultad de Odontología Departamento de Salud Oralspa
dc.relation.ispartofDepartamento de Salud Oralspa
dc.relation.referencesBuitrago Osuna, Asterlis (2019) Micro-filtración de bacterias en la interfase implante-pilar en implantes de conexión interna cónica sometidos a carga dinámica in-vitro. Maestría thesis, Universidad Nacional de Colombia - Sede Bogotá.spa
dc.rightsDerechos reservados - Universidad Nacional de Colombiaspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.licenseAtribución-NoComercial 4.0 Internacionalspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/spa
dc.subject.proposalCarga bacterianaspa
dc.subject.proposalImplantes dentalesspa
dc.subject.proposalInterfase implante-pilarspa
dc.subject.proposalTitaniospa
dc.subject.proposalMicrobiologíaspa
dc.subject.proposalCAD/CAMspa
dc.subject.proposalBiomecánicaspa
dc.subject.proposalBacterial loadspa
dc.subject.proposalDental implantsspa
dc.subject.proposalImplant-abutment interfacespa
dc.subject.proposalTitaniumspa
dc.subject.proposalMicrobiologyspa
dc.titleMicro-filtración de bacterias en la interfase implante-pilar en implantes de conexión interna cónica sometidos a carga dinámica in-vitrospa
dc.typeTrabajo de grado - Maestríaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_bdccspa
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/masterThesisspa
dc.type.redcolhttp://purl.org/redcol/resource_type/TMspa
dc.type.versioninfo:eu-repo/semantics/acceptedVersionspa
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2spa

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
1032393539.2019.pdf
Tamaño:
1.57 MB
Formato:
Adobe Portable Document Format